CLGQF - 301007, FORMULA 815GD

  • MSDS: CLGQF
  • Manufacturer: BRULIN AND CO INC
  • Product Name: 301007, FORMULA 815GD
  • National Stock Number: 6850-01-392-8439
Product Identification

Product ID:301007, FORMULA 815GD
MSDS Date:05/04/1999
FSC:6850
NIIN:01-392-8439
Status Code:A
MSDS Number: CLGQF

Responsible Party
BRULIN AND CO INC
2920 DR ANDREW J BROWN AVE
INDIANAPOLIS, IN 46205-0270
US

Emergency Phone: 800-424-9300

Info Phone: 317-923-3211

Cage: 94058

Contractor
BRULIN AND CO INC
270 INDIANAPOLIS, IN 46205-0270 US

Telephone: 317-923-3211

Cage: 94058

Ingredients

THIS PRODUCT CONTAINS NO HAZARDOUS SUBSTANCES AT 1.0% OR

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:DIRECT EYE CONTACT AND PROLONGED OR
REPEATED SKIN CONTACT MAY CAUSE IRRITATION SEEN AS REDNESS.
Explanation of Carcinogenicity:THIS PRODUCT CONTAINS NO CARCINOGENS AT
0.1% OR MORE LISTED IN NTP ANNUAL REPORT ON CARCINOGENS, IARC
MONOGRAPHS, OR 29 CFR 1910.1201.
Effects of Overexposure:IRRITATION AS NOTED ABOVE.
Medical Cond Aggravated by Exposure:NONE KNOWN

First Aid

First Aid:EYE CONTACT: FLUSH WITH LARGE AMONTS OF WATER FOR 15 MIN.
LIFTNG UPPER & LOWER LIDS OCCASIONALLY. GET MEDICAL ATTENTION.
INHALTION: REOMVE TO FRESH AIR. SKIN CONTACT: WASH WITH MILD SOAP
AND WATER. RE MOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE REUSE.
INGESTION: IF CONSCIOUS, DILUTE BY GIVING 2 GLASSES OF WATER. CALL
PHYSICIAN OR LOCAL POISON CONTROL CENTER IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Extinguishing Media:NONE
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT INCLUDING
SELF-CONTAINED BREATHING APPARATUS SHOULD BE USED. DURING EMERGENCY
CONDITIONS, OVEREXPOSURE TO DECOMPOSITION PRODUCTS MAY CAUSE A
HEALTH HAZARD. SYMPTOMS MAY NOT B E IMMEDIATELY APPARENT. GET
MEDICAL ATTENTION. WATER MAY BE USED TO COOL/ PROTECT CLOSED
CONTAINERS EXPOSED TO HEAT.
Unusual Fire/Explosion Hazard:NONE KNOWN. CLOSED CONTAINERS MAY EXPLODE
(DUE TO BUILD-UP OF PRESSURE) WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:ABSORB ON SOLID ABSORBENT AND SHOVEL INTO
CONTAINERS FOR DISPOSAL.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
BETWEEN 40 AND 120 F.
Other Precautions:HMIS HAZARD RATINGS: HEALTH=1, FLAMMABILITY-0,
REACTIVITY-0.

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED, HOWEVER, IF THE POTENTIAL
FOR OVEREXPOSURE EXISTS, WEAR A NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:MECHANICAL (GENERAL): SUFFICIENT
Protective Gloves:RECOMMENDED (RUBBER)
Eye Protection:SAFETY GOGGLES OR FULL FACE SHIELD RECOMMENDED.
Other Protective Equipment:SUFFICIENT TO MINIMIZE SKIN CONTACT.
Work Hygienic Practices:USE ONLY WITH ADEQUATE VENTILATION. AVOID
BREATHING VAPOR AND MIST. AVOID CONTACT WITH SKIN AND EYES. DO NOT
TAKE INTERNALLY. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
IDENTITY: FORMULA 815GD. PRODUCT NUMBER: 301007.

Chemical Properties

HCC:N1
Boiling Pt:=100.C, 212.F
Melt/Freeze Pt:=-1.1C, 30.F
M.P/F.P Text:APPROX.
Vapor Pres:APPROX 17 @ 68 F
Vapor Density:APPROX 0.6
Spec Gravity:1.075
Evaporation Rate & Reference:1.0 (WATER=1)
Solubility in Water:COMPLETE
Appearance and Odor:BLUE GREEN, NON-VISCOUS LIQUID WITH A MILD ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND STRONG OXIDIZERS.
Stability Condition to Avoid:FREEZING.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE AND
OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE ACCORDING TO FEDERAL, STATE AND LOCAL
LAWS AND 40 CFR.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Regulatory

SARA Title III Information:NO COMPONENTS OF THIS PRODUCT ARE SUBJECT TO
THE REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY PLANNING
AND COMMUNITY RIGHT-TO-KNOWN ACT OF 1986.